Outside Air Temperature Indicator Calibration: Calibration
The outside air temperature indicator's displayed temperature can be recalibrated ±5 °F (±3 °C) to meet the customer's expectations.
- Turn the ignition switch to ON (II).
- Push and hold the INFORMATION (NEXT or PREVIOUS) button for at least 3 seconds to enter the customizing mode.
- While in the customizing mode, select the "CHG SETTING", and enter the "METER SETUP." Then select the "ADJUST OUTSIDE TEMP. DISPLAY", and calibrate the value with the SEL/RESET switch and the INFORMATION (NEXT or PREVIOUS) switch.
- When the desired correction value appears on the display, release the button, and the recalibrated outside air temperature will be displayed.
Example:
Incorrect value = 68°F (20 °C)
Desired correction value = +2°F (+1 °C)
Correct value = 70°F (21 °C)
Desired correction value = -2°F (-1 °C)
Correct value = 66°F (19 °C)
NOTE: The recalibration temperature is not the value the sensor sees.Therefore the temperature can only be adjusted ±5 degrees from sensors.
NOTE: To recalibrate the display to the true temperature, remove the outside air temperature sensor (A), but leave it connected. Submerge the sensor and a thermometer (B) in a container of ice water (C). Select the calibration mode as described above, then recalibrate the display to the true temperature.NOTE: The snow mark is displayed when the temperature is 37 °F (3 °C) or less the first time you turn the ignition switch to ON (II).