Outside Air Temperature Indicator Calibration: Calibration

The outside air temperature indicator's displayed temperature can be recalibrated +5°F (or +3°C) to meet the customer's expectations.

  1. Turn the ignition switch ON (II).
  2. Select the odometer/trip A or odometer/trip B display.
  3. Press and hold the RESET switch for 10 seconds. While you continue to hold the button, the display will scroll through temperature settings from +5°F to -5°F (or +3°C to -3°C) as shown.
    Fig 1: Information Display - Temperature
    G05593105Courtesy of AMERICAN HONDA MOTOR CO., INC.
  4. When the desired correction value appears on the display, release the button, and the recalibrated outside air temperature will be displayed.

    Each time a desired correction valve is entered, it replaces the previous valve.

    Example: 

    Incorrect value = 68°F (20°C) 

    Desired correction valve = +2°F (+1°C) 

    Correct valve =70°F (21°C) 

    Desired correction valve = -2°F (-1°C) 

    Correct valve = 66°F (19°C) 

    NOTE: The recalibration temperature is not the value the sensor sees. Therefore the temperature can only be adjusted ± degrees from the sensor.
    NOTE: To recalibrate the display to the true temperature, remove the outside air temperature sensor (A), but leave it connected. Submerge the sensor and a thermometer (B) in a container of ice water (C). Select the calibration mode as described above, then recalibrate the display to the true temperature.
    Fig 2: Calibrating Display To True Temperature Indicated By Sensor
    G05593106Courtesy of AMERICAN HONDA MOTOR CO., INC.