Rewriting the ODO Data and Transferring the Maintenance Minder Data to a New Gauge Control Module
NOTE:
- If the HDS retrieves the ODO data from the gauge control module, the ODO value on the LCD display will appear as"- - -", making the ODO function unusable, and the HDS will be unable to retrieve additional ODO values.
- Rewriting is not possible on a gauge control module that does not communicate.
- Obtain a new gauge control module before starting the rewriting process.
- Before replacing the gauge control module, connect the HDS to the data link connector.
- Select GAUGES from the BODY ELECTRICAL menu display.
- Select "Gauge Control Module Replacement (ODO rewrite)" from the ADJUSTMENT menu, and follow the instructions on the display to retrieve the ODO value.
- Replace the gauge control module.
- Follow the instructions on the display to write the new ODO value to the new gauge control module.