LEMON Manuals: Even more car manuals for everyone
Home >> Honda >> 2007 >> Element SC, Automatic >> Repair and Diagnosis >> Accessories & Equipment >> Gauges & Instrument Panels >> Gauges >> Outside Air Temperature Indicator Calibration >> Calibration

Outside Air Temperature Indicator Calibration: Calibration

The outside air temperature indicator's displayed temperature can be recalibrated ±5°F (or ±3°C) to meet the customer's expectations.

  1. Turn the ignition switch to ON (II).
  2. Select the odometer display by pressing the TRIP/RESET switch until odometer displayed.
  3. Press and hold the TRIP/RESET switch button. After 10 seconds, the display will scroll through temperature settings from +5°F to -5°F (or +3°C to -3°C) as shown below.
    Fig 1: Identifying Outside Air Temperature Sensor Graph
    G00486250Courtesy of AMERICAN HONDA MOTOR CO., INC.
  4. When the desired correction value appears on the display, release the button, and the recalibrated outside air temperature will be displayed.

    Example: 

    Incorrect value = 68°F (20°C) 

    Desired correction value = +2°F (+1°C) 

    Correct value = 70°F (21°C) 

    Desired correction value = -2°F (-1°C) 

    Correct value = 66°F (19°C) 

    NOTE: The recalibration temperature is not the value the sensor sees. Therefore the temperature can only be adjusted ±5 degrees from the sensor.
    NOTE: To recalibrate the display to the true temperature, remove the outside air temperature sensor (A), but leave it connected. Submerge the sensor and a thermometer (B) in a container of ice water (C). Select the calibration mode as described above, then recalibrate the display to the true temperature.
    Fig 2: Identifying Outside Air Temperature Sensor Recalibration Procedure
    G00486251Courtesy of AMERICAN HONDA MOTOR CO., INC.