Outside Air Temperature Indicator Calibration: Calibration

The outside air temperature indicator's displayed temperature can be recalibrated 3°F to meet the customer's expectations.

  1. Turn the ignition switch ON (II).
  2. Push and hold the trip/reset switch for 10 seconds. While you continue to hold the button, the display will scroll through temperature settings from +3°F to -3°F as shown.
    Fig 1: Display Scrolling Through Temperature Settings
    G01474496Courtesy of AMERICAN HONDA MOTOR CO., INC.
  3. When the desired correction value appears on the display, release the buttons, and the recalibrated outside air temperature will be displayed.

    Each time a desired correction value is entered, it replaces the previous value.

    Example: 

    Incorrect value =  68°F

    Desired correction value =  +2°F

    Corrected value =  70°F

    Desired correction value =  - 2°F

    New corrected value =  66°F

    NOTE: To recalibrate the display to the true temperature, remove the outside air temperature sensor (A), but leave it connected. Submerge the sensor and a thermometer (B) in a container of ice water (C). Select the calibration mode as described above, then recalibrate the display to the true temperature.
    Fig 2: Removing Outside Air Temperature Sensor
    G01474497Courtesy of AMERICAN HONDA MOTOR CO., INC.