The PCM controls transaxle shifting by delivering an output signal to shift control solenoid valves "A" and "B". Shift control solenoid valves are operated in accordance with gear position. See SHIFT CONTROL SOLENOID VALVE OPERATION  table. Shift control solenoid valve assembly is located on transaxle. See Figure.

SHIFT CONTROL SOLENOID VALVE OPERATION

Selector Lever Position Solenoid Valve "A" Solenoid Valve "B"
"D"
1st Gear Off On
2nd Gear On On
3rd Gear On Off
4th Gear Off Off
"2" On On
"1" Off On