Shift Control Solenoid Valves
WARNING: This page is about a different variant/trim than selected.
The PCM controls transaxle shifting by delivering an output signal to shift control solenoid valves "A" and "B". Shift control solenoid valves are operated in accordance with gear position. See SHIFT CONTROL SOLENOID VALVE OPERATION table. Shift control solenoid valve assembly is located on transaxle. See Figure.
SHIFT CONTROL SOLENOID VALVE OPERATION
| Selector Lever Position | Solenoid Valve "A" | Solenoid Valve "B" | |
|---|---|---|---|
| "D" | |||
| 1st Gear | Off | On | |
| 2nd Gear | On | On | |
| 3rd Gear | On | Off | |
| 4th Gear | Off | Off | |
| "2" | On | On | |
| "1" | Off | On | |
| "R" | On | Off | |