Circuit Description
When ignition is first turned on, SDM performs tests to diagnose critical malfunctions within itself. Next SDM measures IGNITION 1 and deployment loop voltages to make sure they are in correct ranges. SDM then proceeds with DEPLOYMENT LOOP CONTINUITY test. During DEPLOYMENT LOOP CONTINUITY test, SDM measures voltage difference between DRIVER-SIDE HIGH and DRIVER-SIDE LOW.