Circuit Description
When ignition is first turned on, SDM performs tests to diagnose critical malfunctions within itself. Next SDM measures IGNITION 1, 23 VLR and deployment loop voltages to make sure they are in correct ranges. SDM measures voltages at DRIVER-SIDE LOW terminal No. 10 and PASSENGER-SIDE LOW terminal No. 3 to detect shorts to ground in air bag module circuits.