Circuit Description
When ignition is first turned on, SDM performs tests to diagnose critical malfunctions within itself. Next SDM measures IGNITION 1 and deployment loop voltages to make sure they are in correct ranges. SDM then proceeds with RESISTANCE MEASUREMENT test. During one portion of RESISTANCE MEASUREMENT test, SDM does following:
- Grounds DRIVER-SIDE LOW terminal No. 10 through internal current sink.
- Connects DRIVER-SIDE LOW terminal No. 9 to internal constant current source. This current produces proportional voltage drops in deployment loop.
- Measures voltage difference between DRIVER-SIDE HIGH and DRIVER-SIDE LOW.
- Calculates resistance of passenger deployment loop using measured voltage.