Load-Sensing Proportioning Valve (LSPV)
- Park vehicle on level surface. Remove all luggage and passengers. Ensure fuel tank is full and spare tire and jack are installed correctly.
- Push LSPV against stopper bolt. Measure spring length. Spring length should be 3.9" (99 mm). If spring length is not within specification, adjust stopper bolt until correct length is obtained.