A-240L (COROLLA LE) LOCK-UP SPEED SPECIFICATIONS (1)

Application MPH
"D" Position (2)
Lock-Up ON 43-48
Lock-Up OFF 40-45
(1) Throttle valve fully closed.
(2) There is no lock-up in "2" or "L" position.
A-241E (CELICA GTS) LOCK-UP SPEED SPECIFICATIONS (1)

Application MPH
"D" Position (2) - NORM
Lock-Up ON in OD 41-43
Lock-Up OFF in OD 37-40
"D" Position (2) - PWR
Lock-Up ON in OD 48-51
Lock-Up OFF in OD 44-47
(1) With throttle valve opened 5 percent.
(2) There is no lock-up in "2" or "L" position.
A-241E (MR2) LOCK-UP SPEED SPECIFICATIONS (1)

Application MPH
"D" Position (2)
Lock-Up ON in OD 50-54
Lock-Up OFF in OD 46-50
(1) With throttle valve opened 5 percent.
(2) There is no lock-up in "2" or "L" position.
A-241L (CELICA ST) LOCK-UP SPEED SPECIFICATIONS (1) (1991)

Application MPH
"D" Position (2)(3)
Lock-Up ON 39-45
Lock-Up OFF 37-43
(1) With throttle fully closed.
(2) There is no lock-up in "2" or "L" position.
(3) Differential gear ratio: 3.034.
A-243L (CELICA ST) LOCK-UP SPEED SPECIFICATIONS (1)

Application MPH
"D" Position (2)(3)
Lock-Up ON 44-50
Lock-Up OFF 37-43
(1) With throttle fully closed.
(2) There is no lock-up in "2" or "L" position.
(3) Differential gear ratio: 3.034.
A-244E (PASEO) LOCK-UP SPEED SPECIFICATIONS (1)

Application MPH
"D" Position (2)
Lock-Up ON in OD 42-45
Lock-Up OFF in OD 39-42
(1) With throttle valve opened 5 percent.
(2) There is no lock-up in "2" or "L" position.