Pattern Select Switch
- Disconnect electrical connector at pattern select switch, located near base of shift lever. See Figure .
- Using ohmmeter, check for continuity between specified wires in accordance with pattern select switch position. See PATTERN SELECT SWITCH CONTINUITY table. Replace pattern select switch if defective. Install electrical connector.
PATTERN SELECT SWITCH CONTINUITY
| Switch Position | Wire Colors |
|---|---|
| NORMAL | Black/Yellow & Blue/Black |
| POWER | Black/Yellow & Black/Pink |