LEMON Manuals: Even more car manuals for everyone
Home >> Genesis >> 2024 >> GV70 2.5T >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Air Conditioning System >> General Safety Information And Caution >> Instructions >> When Handling Refrigerant

When Handling Refrigerant

  1. R-1234yf liquid refrigerant is highly volatile. A drop on the skin of your hand could result in localized frostbite. When handling the refrigerant, be sure to wear gloves.
  2. It is standard practice to wear goggles or glasses to protect your eyes, and gloves to protect your hands. If refrigerant splashes into your eyes, immediately wash them with clean water.
  3. The R-1234yf container is highly pressurized. Never leave it in a hot place, and check if storage temperature is below 52°C (126°F)
  4. An electronic leak detector should be used to check the system for refrigerant leakage. Bear in mind that the R-1234yf, upon coming into contact with flame, produces phosgene, a highly toxic gas.
  5. Use only recommended lubricant for R-1234yf systems. If lubricants other than the recommended one are used, system failure may occur.
  6. PAG lubricant absorbs moisture from the atmosphere at a rapid rate, therefore the following precautions must be observed:
    • When removing refrigerant components from a vehicle, cap the components immediately to prevent entry of moisture.
    • When installing refrigerant components to a vehicle, do not remove the cap until just before connecting the components.
    • Complete the connection of all refrigerant tubes and hoses without delay to prevent the A/C system from taking on moisture.
    • Use the recommended lubricant from a sealed container only.
  7. If an accidental discharge in the system occurs, ventilate the work area before resuming the service.
G16856412Courtesy of HYUNDAI MOTOR AMERICA