When Handling Refrigerant
- R-1234yf liquid refrigerant is highly volatile. A drop on the skin of your hand could result in localized frostbite. When handling the refrigerant, be sure to wear gloves.
- It is standard practice to wear goggles or glasses to protect your eyes, and gloves to protect your hands. If refrigerant splashes into your eyes, immediately wash them with clean water.
- The R-1234yf container is highly pressurized. Never leave it in a hot place, and check if storage temperature is below 52°C (126°F)
- An electronic leak detector should be used to check the system for refrigerant leakage. Bear in mind that the R-1234yf, upon coming into contact with flame, produces phosgene, a highly toxic gas.
- Use only recommended lubricant for R-1234yf systems. If lubricants other than the recommended one are used, system failure may occur.
- PAG lubricant absorbs moisture from the atmosphere at a rapid rate, therefore the following precautions must be observed:
- When removing refrigerant components from a vehicle, cap the components immediately to prevent entry of moisture.
- When installing refrigerant components to a vehicle, do not remove the cap until just before connecting the components.
- Complete the connection of all refrigerant tubes and hoses without delay to prevent the A/C system from taking on moisture.
- Use the recommended lubricant from a sealed container only.
- If an accidental discharge in the system occurs, ventilate the work area before resuming the service.