LEMON Manuals: Even more car manuals for everyone
Home >> Genesis >> 2024 >> GV70 2.5T >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Air Conditioning System >> Evaporator Temperature Sensor >> Inspection

Evaporator Temperature Sensor: Inspection

  1. Turn the ignition switch ON.
  2. Turn the A/C switch ON.
  3. Measure resistance between terminal "+" and "-" of the evaporator temperature sensor.
G16856465Courtesy of HYUNDAI MOTOR AMERICA
Evaporator core temperature [°C (°F)] Min. Resistance [KΩ] Mid. Resistance [KΩ] Max. Resistance [KΩ]
-10 (14) 42.92 43.35 43.78
0 (32) 27.35 27.62 27.89
10 (50) 17.89 18.07 18.25
20 (68) 11.99 12.11 12.23
30 (89) 8.22 8.30 8.38
40 (104) 5.76 5.81 5.86