Automatic Stop Operation Check
- Operate the motor at low speed using the stalk control.
- Stop the motor operation anywhere except at the off position by disconnecting terminal 3.
- Connect the positive (+) lead from the battery to terminal 3 and the negative (-) lead to terminal 1.
- Check that the motor stops running at the off position.