Tolerance Calibration Outline
Information
- SVM calibration tool is required to perform tolerance calibration as shown below.
- Refer to the information below to purchase the SVM calibration tool.
- Tool Name : GDS SVM HYUNDAI (SVM-100)
- Representative purchase consultation email : sales@gitauto.com / purchase@gitauto.com
Tolerance calibration compensates for the error margins of surround view video that occur due to the installation tolerance when the four cameras that comprise the SVM system are installed.
NOTE:
- Tolerance calibration must be performed when the following actions are performed.
- When removing and installing a SVM camera.
- When conducting a body task such as the trunk task that causes the focus of the SVM camera to change.
- When replacing the outside rear view mirror with a SVM camera.
- When replacing the ADAS Parking ECU.