Repair Procedures: Inspection
WARNING: This page is about a different variant/trim than selected.
- Immerse the thermostat in water and gradually heat the water.
- Check the valve opening temperature.
Valve opening temperature:
82 ± 1.5°C (179.6 ± 2.7°F)
Full opening temperature : 95°C (203°F)
If the valve opening temperature is not as specified, replace the thermostat.
- Check the valve lift.
Valve lift : 8 mm (0.3 in) or more at 95°C (203°F)
If the valve lift is not as specified, replace the thermostat.