LEMON Manuals: Even more car manuals for everyone
Home >> Genesis >> 2022 >> GV80 3.5T Advanced+ >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 12 (Engine Control System - 2.5L) >> Canister Close Valve (CCV) >> Repair Procedures >> Inspection

Repair Procedures: Inspection

WARNING: This page is about a different variant/trim than selected.
  1. Turn the ignition switch OFF.
  2. Disconnector canister close valve connector.
  3. Measure resistance between the canister close valve terminals 1 and 2.
    G14721451Courtesy of HYUNDAI MOTOR AMERICA
  4. Check that the resistance is within the specification.

    Specification  : 19.5 - 22.5 [20°C (68°F)]

  5. Disconnect the vapor hose connected with the canister from the CCV.
  6. Connect a vacuum pump to the nipple.
  7. Apply vacuum to the valve with the battery power (B +) applied.

    Specification  : Vacuum maintained