Home >> Genesis >> 2021 >> G90 5.0 Ultimate, RWD >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 32 (Engine Control System Diagnosis - 3.3L (4 Of 9)) >> DTC P0244-00: Turbocharger/Supercharger Wastegate Sol. 'A' Range/Performance >> Component Inspection >> EWGA Actuation test

EWGA Actuation test

WARNING: This page is about a different variant/trim than selected.
  1. Connect GDS and select "Actuation Test" mode.
  2. Start the engine.
  3. Start 'Turbo Charger Bypass Valve' item.
    G14204643Courtesy of HYUNDAI MOTOR AMERICA
  4. Is parameter displayed within specifications?

    YES 

    • Check for poor connection between ECM and component: backed out terminal, improper mating, broken locks or poor terminal to wire connection. Repair as necessary and go to "VERIFICATION OF VEHICLE REPAIR " procedure.

    NO 

    • Substitute with a known - good EWGA and check for proper operation. If the problem is corrected, replace EWGA and go to "VERIFICATION OF VEHICLE REPAIR " procedure.