LEMON Manuals: Even more car manuals for everyone
Home >> Genesis >> 2021 >> G90 5.0 Ultimate, RWD >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 30 (Engine Control System Diagnosis - 3.3L (5 Of 9)) >> DTC P0441-00: Evaporative Emission System Incorrect Purge Flow >> System Inspection

System Inspection

WARNING: This page is about a different variant/trim than selected.
  1. IG "OFF"
  2. Disconnect the hose leading from the PCSV to intake manifold at intake manifold.
  3. Using a vacuum pump, apply vacuum to the manifold side of the vacuum hose and verify PCSV holds vacuum.
  4. IG "ON" & Engine "OFF".
  5. Install GDS and select "Canister Purge Valve" on the Actuation Test mode
  6. Activates "Canister Purge Valve" by clicking "Start" icon.
  7. Verify PCSV release vacuum while valve is activating (should hear a faint click from PCSV)
  8. Repeat this procedure 4 or 5 times to ensure PCSV reliability.

    Specification 

    Test Condition Specification
    PCSV is ON (should hear a faint click from PCSV) Holds vacuum
    PCSV is OFF Release vacuum
  9. Is PCSV working properly?

    YES 

    NO 

    • Verify arrow on PCSV is pointing towards intake manifold. If it is not, reverse installation. Reinstall as necessary and go to "VERIFICATION OF VEHICLE REPAIR " procedure.
    • If OK, thoroughly check fuel vapor hoses and hose clamps between PCSV and intake manifold. Repair as necessary. If OK, test with a new PCSV and check for proper operation. If problem is corrected, replace PCSV and go to "VERIFICATION OF VEHICLE REPAIR " procedure.