- Immerse thermostat in coolant heated to over 95°C (203°F), then heat for at least 3 minutes to check valve lift.NOTE:
- Do not immerse connector part.
- Do not directly heat unit as this will damage thermostat.
- Check the valve opening temperature.
Valve opening temperature: 95 ± 2°C (203 ± 35.6°C)
Full opening temperature: 100°C (212°F)
If the valve opening temperature is not as specified, replace the thermostat.
- Check the valve lift.
Valve lift: 8 mm (0.3 in) or more at 100°C (212°F)