Repair Procedures: Inspection
WARNING: This page is about a different variant/trim than selected.
- After disconnecting the vapor hose from the PCV valve, remove the PCV valve.
- Reconnect the PCV valve to the vapor hose.
- Run the engine at idle, then put a finger over the open end of the PCV valve and make sure that intake manifold vacuum can be felt.
- If vacuum could not be felt, inspect the PCV operation. If operating correctly, clean or replace the vapor hose.