K33 HVAC Control Module X2
Connector Part Information
|
Terminal Part Information
| Terminal Type ID | Terminated Lead | Diagnostic Test Probe | Terminal Removal Tool |
|---|---|---|---|
| I | 13584547 | J-35616-64B (L-BU) | J-38125-215A |
| Pin | Size | Color | Circuit | Function | Terminal Type ID | Option |
|---|---|---|---|---|---|---|
| 1 | 0.35 0.35 |
RD / GN RD / GN |
742 742 |
Battery Positive Voltage Battery Positive Voltage |
I I |
((C67) /(CJ2+(UE1)) -KEM CJ2-(UE1/UI3) |
| 2 | 0.35 | GN | 5060 | Low Speed GMLAN Serial Data | I | - |
| 3 | 0.35 | GN | 5060 | Low Speed GMLAN Serial Data | I | - |
| 4 | 0.35 | GN / YE | 7531 | HVAC Control Module LIN Bus 1 | I | - |
| 5 | - | - | - | Not Occupied | - | - |
| 6 | 0.35 0.35 |
GN / BU GN / BU |
4119 4119 |
HVAC Control Module LIN Bus 2 HVAC Control Module LIN Bus 2 |
I I |
ASV+UEU ASV-UEU |
| 7 | - | - | - | Not Occupied | - | - |
| 8 | 0.35 | BK | 1650 | Ground | I | - |
| 9 | 0.35 | VT / GN | 39 | Run/Crank Ignition 1 Voltage | I | - |
| 10 | 0.35 | BU / YE | 7574 | Air Conditioning Compressor Solenoid Valve Control | I | - |
| 11 | 0.35 | BU / BN | 7573 | Air Conditioning Compressor Solenoid Valve Control | I | - |
| 12 - 14 | - | - | - | Not Occupied | - | - |
| 15 | 0.5 | BU / GY | 754 | Blower Motor Speed Control | I | - |
| 16 - 17 | - | - | - | Not Occupied | - | - |
| 18 | 0.35 | BK / GN | 7567 | Solar Sensor Low Reference | I | CJ2+(UE1/C67) |
| 19 | 0.35 | BN / VT | 193 | Rear Defogger Relay Control | I | - |
| 20 | - | - | - | Not Occupied | - | - |