Diagnostic Aids
Rail Over-Voltage Exposure Time
| High Voltage Component |
Battery Energy Control Module scan tool parameters |
Maximum Lifetime Over-Voltage Exposure Time Limit |
| K107A Drive Motor 1 Control Module |
- Drive Motor Control Module - Positive Rail Over-voltage Exposure
- Drive Motor Control Module - Negative Rail Over-voltage Exposure
|
7200 Seconds |
| K107B Drive Motor 2 Control Module |
- Drive Motor Control Module 2 - Positive Rail Over-voltage Exposure
- Drive Motor Control Module 2 - Negative Rail Over-voltage Exposure
|
7200 Seconds |
| K107C Drive Motor Control Module 3 |
- Drive Motor Control Module 3 - Positive Rail Over-voltage Exposure
- Drive Motor Control Module 3 - Negative Rail Over-voltage Exposure
|
7200 Seconds |
| E54V Hybrid/Electric Vehicle Coolant Heater |
- Hybrid/Electric Vehicle Coolant Heater - Positive Rail Over-voltage Exposure
- Hybrid/Electric Vehicle Coolant Heater - Negative Rail Over-voltage Exposure
|
600 Seconds |
| G1HV Air Conditioning With Motor Compressor |
- Air Conditioning Electric Compressor - Positive Rail Over-voltage Exposure
- Air Conditioning Electric Compressor - Negative Rail Over-voltage Exposure
|
7200 Seconds |
T18 Battery Charger (Includes 14V Power Module) |
- Battery Charger Control Module - Positive Rail Over-voltage Exposure
- Battery Charger Control Module - Negative Rail Over-voltage Exposure
- 14 Volt Power Module - Positive Rail Over-voltage Exposure
- 14 Volt Power Module - Negative Rail Over-voltage Exposure
|
7200 Seconds |