X419 Body Harness to Power Inverter Module Jumper Harness (KI5)
Connector Part Information
|
Connector Part Information
|
Terminal Part Information
| Terminal Type ID | Terminated Lead | Diagnostic Test Probe | Terminal Removal Tool |
|---|---|---|---|
| I | 13575850 | J-35616-14 (GN) | J-38125-557 |
| II | 84962855 | J-35616-4A (PU) | J-38125-11A |
| III | Not required | J-35616-3 (GY) | No Tool Required |
| IV | Not required | J-35616-5 (PU) | No Tool Required |
| Pin | Size | Color | Circuit | Terminal Type ID | Option | Function | Pin | Size | Color | Circuit | Terminal Type ID | Option |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1 | 0.75 | BK | 686 | II | - | 230 VAC Outlet Phase A 230 VAC Outlet Phase A |
1 | 0.75 0.75 |
BN BK |
686 686 |
IV IV |
- - |
| 2 | 0.5 | VT/RD | 4049 | I | - | AC Power Outlet Sensor High Reference | 2 | 0.5 | VT/RD | 4049 | III | - |
| 3 | 0.5 | VT/WH | 1139 | I | - | Run/Crank Ignition 1 Voltage | 3 | 0.5 | VT/WH | 1139 | III | - |
| 4 | 0.5 | WH/GN | 4628 | I | - | DC/AC Inverter Relay Control | 4 | 0.5 | WH/GN | 4628 | III | - |
| 5 | 0.75 | BU/BN | 6807 | I | - | DC/AC Inverter Control | 5 | 0.5 | BU/BN | 6807 | III | - |
| 6 | - | - | - | - | - | Not Occupied | 6 | - | - | - | - | - |
| 7 | 0.5 | BK/WH | 2262 | II | - | 230V AC Phase A 2 | 7 | 0.75 | BN/WH | 2262 | IV | - |
| 8 | 0.75 | RD | 6865 | II | - | 230V AC Phase B | 8 | 0.75 | BU | 6865 | IV | - |
| 9 | 0.5 | Bare | 2526 | I | - | 230V AC Outlet Low Reference | 9 | 0.5 | BARE | 2526 | III | - |
| 10 | 0.5 | GN/BU | 6133 | I | - | Body Control Module LIN Bus 2 | 10 | 0.5 | GN/BU | 6133 | III | - |
| 11 | - | - | - | - | - | Not Occupied | 11 | - | - | - | - | - |
| 12 | 0.75 | GN/BN | 2266 | I | - | DC/AC Inverter Control 2 | 12 | 0.5 | GN/BN | 2266 | III | - |
| 13 | 0.5 | BARE | 2544 | I | - | 230V AC Outlet 2 Low Reference | 13 | 0.5 0.5 |
BARE Bare |
2544 2544 |
III III |
- - |
| 14 | 0.5 | RD/WH | 2263 | II | - | 230V AC Phase B 2 | 14 | 0.75 | BU/WH | 2263 | IV | - |