Circuit/System Verification
- Ignition ON.
- Verify the DTC P0461, P0462, P0463, or P0464 are not set
- If DTC P0461, P0462, P0463, or P0464 are set
Refer to Circuit/System Testing
- Go to next step: If DTC P0461, P0462, P0463, or P0464 are not set
- If DTC P0461, P0462, P0463, or P0464 are set
- If equipped, verify the mechanical fuel level gauge sweeps during Ignition Instrument Panel Cluster initialization.
- If the fuel level gauge does not sweep
Replace the P16 Instrument Panel Cluster Control Module.
- Go to next step: If the fuel level gauge sweeps
- If the fuel level gauge does not sweep
- Ignition ON, Verify the low fuel level indicator turns ON and OFF during Instrument Panel Cluster initialization bulb check.
- If the low fuel level indicator does not turn ON and OFF
Replace the P16 Instrument Panel Cluster Control Module
- Go to next step: If the low fuel level indicator turns ON and OFF
- If the low fuel level indicator does not turn ON and OFF
- Verify the scan tool Fuel Level Sensor parameter is between 5 - 95% and varies with fuel level.
- If not between 5 - 95% or does not vary with fuel level
Refer to Circuit/System Testing
- Go to next step: If between 5 - 95% and varies with fuel level
- If not between 5 - 95% or does not vary with fuel level
- All OK.