Removal Procedure
- Disconnect the battery negative cable. Battery Negative Cable Disconnection and Connection
- Remove the electrical harness bracket nuts (1).
- Remove the electrical harness bracket (2) from the control valve body cover and position out of the way.
- Drain the transmission fluid. Transmission Fluid Drain and Fill
- Disconnect the control valve body transmission control module electrical connector (1), then unclip the wiring harness from the cover.
- Transmission Fluid Cooler Inlet Pipe (1) @ Transmission - Disconnect - Transmission Fluid Cooler Inlet and Outlet Pipe Replacement (LSY)
- Transmission Fluid Cooler Outlet Pipe (2) @ Transmission - Disconnect - Transmission Fluid Cooler Inlet and Outlet Pipe Replacement (LSY)
- Remove the body ground cable and wiring harness assembly mounting bolt at front of transmission and position ground cable and harness out of the way.
- Remove the control valve body cover bolts (1, 2).
- Remove the control valve body cover (1).
- Clean the transmission case and control valve body cover gasket surfaces. Inspect and replace the gasket as necessary.