Component Testing
WARNING: This page is about a different variant/trim than selected.
Static Test
- Ignition/Vehicle - Off
- Disconnect the appropriate electrical connector : Q6 Camshaft Position Actuator Solenoid Valve
- Test for 6 to 12 ohms between the test points : Control terminal 1/A & Low Reference terminal 2/B
- If not between 6 and 12 ohms
Replace the component : Q6 Camshaft Position Actuator Solenoid Valve
- Go to next step : If between 6 and 12 ohms
- If not between 6 and 12 ohms
- Test for infinite resistance between the test points : Each terminal of the component & The component's housing
- If less than infinite resistance
Replace the component : Q6 Camshaft Position Actuator Solenoid Valve
- Go to next step : If infinite resistance
- If less than infinite resistance
- All OK.
Dynamic Test
- Ignition/Vehicle - Off
- Disconnect the appropriate electrical connector : Q6 Camshaft Position Actuator Solenoid Valve
- Connect a jumper wire between the test points : Low Reference terminal 2/B & Ground
- Momentarily connect a 7.5 A fused jumper wire between the test points : Control terminal 1/A & B+
Verify the component turns On and Off when connecting and disconnecting the jumper wire : Q6 Camshaft Position Actuator Solenoid Valve
- If the component does not turn On and Off
Replace the component : Q6 Camshaft Position Actuator Solenoid Valve
- Go to next step : If the component turns On and Off
- If the component does not turn On and Off
- All OK.