M6L Air Temperature Door Actuator - Left (CJ2)
| Connector Part Information Harness Type: HVAC OEM Connector: Not Available Service Connector: Service by Harness - See Part Catalog Description: 6 -Way |
Terminal Part Information
| Terminal Type ID | Terminated Lead | Diagnostic Test Probe | Terminal Removal Tool |
| I | Not required | Not Available | No Tool Required |
| Pin | Size | Color | Circuit | Function | Terminal Type ID | Option |
|---|---|---|---|---|---|---|
| 1 | 0.35 | GN | 3169 | Air Temperature Door Actuator Control 1 | I | - |
| 2 | 0.75 | OG | 7572 | HVAC Door Actuator Control | I | - |
| 3 | 0.35 | WH/PK | 3170 | Air Temperature Door Actuator Control 2 | I | - |
| 4 | 0.35 | GY/RD | 3171 | Air Temperature Door Actuator Control 3 | I | - |
| 5 | - | - | - | Not Occupied | - | - |
| 6 | 0.35 | RD/BK | 3172 | Air Temperature Door Actuator Control 4 | I | - |