K115 Reductant Control Module X2 (LWN)
Courtesy of GENERAL MOTORS COMPANY
|
Connector Part Information
- Harness Type: Reductant Assembly
- OEM Connector: 13504367
- Service Connector: Service by Harness - See Part Catalog
- Description: 20 <p01>-Way F 1.5 Series, Sealed(BK)
|
Terminal Part Information
| Terminal Type ID |
Terminated Lead |
Diagnostic Test Probe |
Terminal Removal Tool |
| I |
Not required |
Not Available |
No Tool Required |
| Pin |
Size |
Color |
Circuit |
Function |
Terminal Type ID |
Option |
| 1 |
1.0 |
OG |
3103 |
Diesel Exhaust Fluid Smart Pump Control |
I |
- |
| 2 |
1.0 |
GN |
3875 |
Diesel Exhaust Fluid Smart Pump Supply Voltage Phase 2 |
I |
- |
| 3 |
1.0 |
BU |
3876 |
Diesel Exhaust Fluid Smart Pump Supply Voltage Phase 3 |
I |
- |
| 4 |
1.0 |
VT |
4318 |
Diesel Exhaust Fluid Tank Heater Low Control |
I |
- |
| 5 |
1.0 |
BK |
3104 |
Diesel Exhaust Fluid Smart Pump Low Reference |
I |
- |
| 6 |
0.35 |
BK / BN |
7285 |
Diesel Exhaust Fluid Liquid Quality Temperature Sensor Low Reference |
I |
- |
| 7 |
0.35 |
YE |
3922 |
Diesel Exhaust Fluid Heater Control 2 |
I |
- |
| 8 |
- |
- |
- |
Not Occupied |
- |
- |
| 9 |
0.5 |
OG |
3244 |
Diesel Exhaust Fluid Tank Temperature Sensor Signal |
I |
- |
| 10 |
0.35 |
GN |
3245 |
Diesel Exhaust Fluid Tank Temperature Sensor Low Reference |
I |
- |
| 11 |
0.35 |
YE |
3921 |
Diesel Exhaust Fluid Heater Control 1 |
I |
- |
| 12 |
0.35 |
BU |
3106 |
Diesel Exhaust Fluid Pressure Sensor 5 Volt Reference |
I |
- |
| 13 |
0.35 |
GY |
3108 |
Diesel Exhaust Fluid Pressure Sensor Signal |
I |
- |
| 14 |
0.35 |
YE |
3107 |
Diesel Exhaust Fluid Pressure Sensor Low Reference |
I |
- |
| 15 - 17 |
- |
- |
- |
Not Occupied |
- |
- |
| 18 |
0.35 |
YE / GN |
7284 |
Diesel Exhaust Fluid Liquid Quality Temperature Signal |
I |
- |
| 19 |
0.35 |
VT / GY |
7286 |
Diesel Exhaust Fluid Sensor Voltage Reference 2 |
I |
- |
| 20 |
0.35 |
VT |
4319 |
Diesel Exhaust Fluid Line Heater Low Control |
I |
- |