Circuit/System Verification
- Ignition ON/Vehicle in Service Mode.
- Verify the scan tool ECM Ambient Air Temperature parameter is between -40°C (-40°F) and +88°C (+190°F) and changes with air temperature changes.
- If not between -40°C (-40°F) and +88°C (+190°F) or changes with air temperature changes
Refer to Circuit/System Testing.
- Go to next step: If between -40°C (-40°F) and +88°C (+190°F) and changes with air temperature changes
- If not between -40°C (-40°F) and +88°C (+190°F) or changes with air temperature changes
- Perform the ECM Ambient Air Temperature Calculation Reset special function with the scan tool
- Verify the scan tool Ambient Air Temperature parameter is within five degrees of actual ambient air temperature.
- If not within five degrees of actual ambient air temperature
Refer to Circuit/System Testing.
- Go to next step: If within five degrees of actual ambient air temperature
- If not within five degrees of actual ambient air temperature
- All OK.