Circuit/System Verification
WARNING: This page is about a different variant/trim than selected.
- Engine running.
- Verify the scan tool the appropriate EGR Temperature Sensor parameter is between -39° to +999°C (-38° to +1, 830°F) and changes with engine run time.
- If not between -39° to +999°C (-38° to +1, 830°F) or does not change
Refer to Circuit/System Testing.
- Go to next step: If between -39° to +999°C (-38° to +1, 830°F) and changes
- If not between -39° to +999°C (-38° to +1, 830°F) or does not change
- Operate the vehicle within the Conditions for Running the DTC. You may also operate the vehicle within the conditions that you observed from the Freeze Frame/Failure Records data.
- Verify that DTC does not set.
- If DTC sets
Refer to Circuit/System Testing.
- Go to next step: If DTC does not set
- If DTC sets
- All OK.