Conditions for Setting the DTC
WARNING: This page is about a different variant/trim than selected.
DTC P227C
The ECM detects that the BARO sensor 2 is less than 50 kPa (7.3 PSI) for greater than 5 s.
DTC P222D
The ECM detects that the BARO sensor 2 is greater than 115 kPa (16.7 PSI) for greater than 5 s.
DTC P227E
The ECM detects that the BARO sensor 2 signal had an accumulated variation, over a 13 ms sample period, of greater than 200 kPa (29.0 PSI) for greater than 50 s.