Conditions for Setting the DTC
P20B9
The ECM indicates the reductant tank heater control circuit is open for greater than 5 s.
P20BA
The ECM indicates the reductant tank heater resistance is greater or less than a calibrated value for greater than 6 s.
P20BB
The ECM indicates the reductant tank heater control circuit is shorted to ground or overloaded for greater than 5 s.
P20BC
The ECM indicates the reductant tank heater control circuit is shorted to a voltage for greater than 5 s.
P20BD
The ECM indicates the reductant line heater control circuit is open for greater than 5 s.
P20BE
The ECM indicates the reductant line heater resistance is greater or less than a calibrated value for greater than 6 s.
P20BF
The ECM indicates the reductant line heater control circuit is shorted to ground or overloaded for greater than 5 s.
P20C0
The ECM indicates the reductant line heater control circuit is shorted to a voltage for greater than 5 s.