Conditions for Setting the DTCs
WARNING: This page is about a different variant/trim than selected.
NOTE:
P0096 Can fail under any of the following 3 sets of conditions.
P0096 - Condition 1
- The ECM determines the absolute difference between IAT sensor 1 start-up temperature and the IAT sensor 2 start-up temperature is greater than 25°C (45°F).
AND
- The ECM determines the absolute difference between IAT sensor 2 start-up temperature and the IAT sensor 3 start-up temperature is greater than 25°C (45°F).
AND
- The ECM determines the absolute difference between IAT sensor 1 start-up temperature and the IAT sensor 3 start-up temperature is less than or equal to 25°C (45°F).
- This DTC runs once per ignition cycle when the enabling conditions are met.
P0096 - Condition 1
- The ECM determines the absolute difference between IAT sensor 1 start-up temperature and the IAT sensor 2 start-up temperature is greater than 25°C (45°F).
AND
- The ECM determines the absolute difference between IAT sensor 2 start-up temperature and the IAT sensor 3 start-up temperature is greater than 25°C (45°F).
AND
- The ECM determines the absolute difference between IAT sensor 1 start-up temperature and the IAT sensor 3 start-up temperature is greater than 25°C (45°F).
- This DTC runs once per ignition cycle when the enabling conditions are met.
P0096 - Condition 3
- The ECM determines the IAT sensor 3 start-up temperature is between the IAT sensor 1 and IAT sensor 2 start-up temperatures.
AND
- The ECM determines the absolute difference between IAT sensor 1 start-up temperature and the IAT sensor 2 start-up temperature is greater than 25°C (45°F).
AND
- The ECM determines the absolute difference between IAT sensor 3 and the IAT sensor 2 start-up temperatures is greater than absolute difference between IAT sensor 3 and the IAT sensor 1 start-up temperatures.
DTC P0096 runs once at the beginning of an ignition cycle when any one of the above 3 enabling sets of conditions is met.
NOTE:
P0111 Can fail under any of the following 3 sets of conditions.
P0111 - Condition 1
- The ECM determines the absolute difference between IAT sensor 1 start-up temperature and the IAT sensor 2 start-up temperature is greater than 25°C (45°F).
AND
- The ECM determines the absolute difference between IAT sensor 1 start-up temperature and the IAT sensor 3 start-up temperature is greater than 25°C (45°F).
AND
- The ECM determines the absolute difference between IAT sensor 2 start-up temperature and the IAT sensor 3 start-up temperature is less than or equal to 25°C (45°F).
P0111 - Condition 2
- The ECM determines the IAT sensor 2 start-up temperature is between the IAT sensor 1 and IAT sensor 3 start-up temperatures.
AND
- The ECM determines the absolute difference between IAT sensor 1 start-up temperature and the IAT sensor 3 start-up temperature is greater than 25°C (45°F).
AND
- The ECM determines the absolute difference between IAT sensor 2 and the IAT sensor 1 start-up temperatures is greater than absolute difference between IAT sensor 2 and the IAT sensor 3 start-up temperatures.
P0111 - Condition 3
- The ECM determines the IAT sensor 3 start-up temperature is between the IAT sensor 1 and IAT sensor 2 start-up temperatures.
AND
- The ECM determines the absolute difference between IAT sensor 1 start-up temperature and the IAT sensor 2 start-up temperature is greater than 25°C (45°F).
AND
- The ECM determines the absolute difference between IAT sensor 3 and the IAT sensor 1 start-up temperatures is greater than absolute difference between IAT sensor 3 and the IAT sensor 2 start-up temperatures.
DTC P0111 runs once at the beginning of an ignition cycle when any one of the above 3 enabling sets of conditions is met.