Component Testing
WARNING: This page is about a different variant/trim than selected.
- Connect a 3 A fused jumper wire between the test points: 5 V Reference terminal 3 & 5 V
- Connect a jumper wire between the test points: Low Reference terminal 1 & Ground
- Test for 2.5 to 4.0 V between the test points: Signal terminal 2 & Low Reference terminal 1
- If not between 2.5 and 4.0 V
Replace the component: B310 Fuel Pressure/Temperature Sensor
- Go to next step: If between 2.5 and 4.0 V
- If not between 2.5 and 4.0 V
- All OK.