Conditions for Setting the DTC
P0133, P015A or P015B
The engine control module detects that the heated oxygen sensor rich-to-lean or lean-to-rich average response time is greater than a calibrated value.
The DTCs set within 60 s when the above condition is met.
P013A
The engine control module detects that the accumulated mass air flow monitored during rich-to-lean transitions between 450-150 mV is greater than 75 grams.
P013B
The engine control module detects that the accumulated mass air flow monitored during lean-to-rich transitions between 300-600 mV is greater than 75 grams.
P013E
The engine control module detects that the heated oxygen sensor voltage has not decreased below 450 mV within a calibrated value of accumulated air flow.
P013F
The engine control module detects that the heated oxygen sensor voltage has not increased above 300 mV within a calibrated value of accumulated air flow.
P2270
The engine control module does not detect a heated oxygen sensor voltage greater than 825 mV before accumulated mass air flow exceeds a calibrated value.
P2271
The engine control module does not detect an heated oxygen sensor voltage less than 100 mV before accumulated mass air flow exceeds a calibrated value.