Circuit/System Verification
WARNING: This page is about a different car, the 2017 GMC Acadia. However, it is still accessible from the selected car via links, so may be relevant.
- Ignition OFF
- Test for 12.0 V at the battery terminals.
- If less than 12.0 V
Refer to Battery Inspection/Test
- If 12.0 V
- If less than 12.0 V
- Verify that there are no A/C lines, heater houses or other accessory equipment misrouted or rubbing against the generator causing the noise to be transmitted into the passenger compartment.
- If there is a line rubbing condition
Reroute or realign the hose or line.
- If there is no line rubbing condition
- If there is a line rubbing condition
- Remove the engine drive belt. Verify all the belt driven devices spin freely and do not produce any unusual sounds.
- If they do not spin freely or they make an unusual sound
Replace the affected component.
- If they spin freely and no unusual sound is given
- If they do not spin freely or they make an unusual sound
- Inspect the generator, its alignment, and its bolt torque.
- If the generator is misaligned or improperly torque
Refer to Generator Replacement (LCV - without Generator Shield) Generator Replacement (LGX) Generator Replacement (LCV - with Generator Shield) .
- If the generator is aligned and torqued properly
- If the generator is misaligned or improperly torque
- Ignition ON
- Engine running idle, verify that the noise concern is not engine related.
- If the noise concern is engine related
Proceed to engine mechanical diagnostic information and procedures for the appropriate engine.
- If the noise concern is not engine related
- If the noise concern is engine related
- Ignition OFF
- Install the engine drive belt.
- Ignition ON, engine running idle.
- Verify the generator is not producing unusual noise.
- If the generator is producing unusual noise
Replace the generator, refer to Generator Replacement (LCV - without Generator Shield) Generator Replacement (LGX) Generator Replacement (LCV - with Generator Shield) .
- If the generator is not producing unusual noise
- If the generator is producing unusual noise
- All OK.