LEMON Manuals: Even more car manuals for everyone
Home >> GMC >> 2018 >> Acadia Denali, FWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 183 (Heating, Ventilation, And Air Conditioning) >> Repair Instructions >> Condenser Outlet Tube Replacement (LGX)

Condenser Outlet Tube Replacement (LGX)

WARNING: This page is about a different car, the 2017 Cadillac ATS. However, it is still accessible from the selected car via links, so may be relevant.
Fig 1: Condenser Outlet Tube (LGX)
GM2838263Courtesy of GENERAL MOTORS COMPANY
Callout Component Name

Preliminary Procedures

  1. Recover the air conditioning system refrigerant. Refer to Refrigerant Recovery and Recharging (R-134a) Refrigerant Recovery and Recharging (R-1234yf) 
  2. Remove the air cleaner assembly. Refer to Air Cleaner Assembly Replacement (LGX)
  3. Remove the left front wheelhouse liner. Refer to Front Wheelhouse Liner Replacement (Non V-Series)
  4. Remove the front compartment air deflector. Refer to Front Compartment Air Deflector Replacement (V Series)
1 Air Conditioning Condenser and Condenser Hose Nut
CAUTION:

Refer to Fastener Caution .


Tighten 
22 N.m (16 lb ft)
2 Air Conditioning Condenser Outlet Tube Bolt
Tighten 
10 N.m (89 lb in)
3 Air Conditioning Condenser Outlet Tube Nut
Tighten 
22 N.m (16 lb ft)
4 Air Conditioning Condenser Outlet Tube Washer (Qty: 2)
Procedure 
Remove and discard the old sealing washers and replace with NEW sealing washers. Refer to Air Conditioning System Seal Replacement 
5 Air Conditioning Condenser Outlet Tube