Conditions for Setting the DTC
P105E
The stop/start capacitor control module detects DC/DC converter temperature less than -50°C.
P105F
The stop/start capacitor control module detects DC/DC converter temperature greater than 155°C.
P1061
The stop/start capacitor control module detects capacitor switch temperature less than -50°C.
P1062
The stop/start capacitor control module detects capacitor switch temperature greater than 160°C.
P1067
The stop/start capacitor control module detects a current greater than 1330 A or less than -1330 A in either internal ground switch.
OR
The stop/start capacitor control module detects an internal power supply is not functional or is out of range.
OR
The stop/start capacitor control module detects the analog inputs are greater than 2.78 V or less than 2.23 V, indicating faulty analog inputs to the A/D converter.
OR
The stop/start capacitor control module detects a capacitor voltage of 5.86 V or greater, indicating the capacitor voltage sensor is stuck at maximum.
P106A
The stop/start capacitor control module detects a voltage drop across the internal ground switch greater than 0.8 V or less than -0.8 V when current is greater than 550 A.
OR
The stop/start capacitor control module detects a voltage drop across the internal ground switch greater than 0.4 V or less than -0.4 V when current is less than or equal to 550 A.
P106B
The stop/start capacitor control module detects an internal ground switch driver voltage bank is less than 10.46 V.
P106C
The stop/start capacitor control module detects an internal ground switch is in high impedance state.
P106D
The stop/start capacitor control module detects the internal safety supply voltage is less than 11.23 V.
P1071
The stop/start capacitor control module detects a failure of the Read Only Memory (ROM).
P1072
The stop/start capacitor control module detects a failure of the Random Access Memory (RAM).
P1073
The stop/start capacitor control module detects a failure of the Erasable Programmable Read Only Memory (EPROM).
P1080
The stop/start capacitor control module detects an internal ground switch bank A gate voltage is less than 10.5 V when switch is commanded close.
P1081
The stop/start capacitor control module detects an internal ground switch bank A gate voltage is greater than 2.0 V when switch is commanded open.
P108A
The stop/start capacitor control module detects the absolute value of the difference between the ground switch bank A and bank B gate voltage is greater than 2.0 V.
P108B
The stop/start capacitor control module detects an internal ground switch bank B gate voltage is less than 10.5 V when switch is commanded close.
P108C
The stop/start capacitor control module detects an internal ground switch bank B gate voltage is greater than 2.0 V when switch is commanded close.
P108D
The stop/start capacitor control module detects the DC/DC converter does not stop charging when requested or is unable to discharge the capacitor
P108E
The stop/start capacitor control module detects the phase 1 charge current is greater than 36.75 A or phase 2 charge current is greater than 68.25 A.
OR
The stop/start capacitor control module detects the DC/DC converter is unable to charge the capacitor
P108F
The stop/start capacitor control module detects that it is unable to switch over to the internal capacitor switch during self test.
OR
The stop/start capacitor control module detects an unintended switchover to the capacitor switch during self test.
OR
The stop/start capacitor control module detects the capacitor switch is in a high impedance state or diode mode during self test.
P1090
The stop/start capacitor control module detects less than 2.18 V or greater than 2.83 V on a 2.5 V reference.
P1091
The stop/start capacitor control module detects capacitor switch current is greater than 60 A and ground switch current is less than -120 A.
OR
The stop/start capacitor control module detects ground switch current is greater than 40 A and capacitor switch current is less than 30 A
OR
The stop/start capacitor control module detects capacitor switch is in a high impedance or in diode mode when it should be closed.
OR
The stop/start capacitor control module detects capacitor switch does not close when it is commanded to close.
OR
The stop/start capacitor control module has reached its end of life.