Home >> GMC >> 2018 >> Acadia Denali, FWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 180 (Battery, Charging System And Starting System) >> Diagnostic Information and Procedures >> DTC P105E, P105F, P1061, P1062, P1067, P106A-P106D, P1071-P1073, P1080, P1081, P108A-P108F, P1090, or P1091: Stop-Start Capacitor >> Conditions for Setting the DTC

Conditions for Setting the DTC

WARNING: This page is about a different car, the 2017 Cadillac ATS. However, it is still accessible from the selected car via links, so may be relevant.

P105E 

The stop/start capacitor control module detects DC/DC converter temperature less than -50°C.

P105F 

The stop/start capacitor control module detects DC/DC converter temperature greater than 155°C.

P1061 

The stop/start capacitor control module detects capacitor switch temperature less than -50°C.

P1062 

The stop/start capacitor control module detects capacitor switch temperature greater than 160°C.

P1067 

The stop/start capacitor control module detects a current greater than 1330 A or less than -1330 A in either internal ground switch.

OR

The stop/start capacitor control module detects an internal power supply is not functional or is out of range.

OR

The stop/start capacitor control module detects the analog inputs are greater than 2.78 V or less than 2.23 V, indicating faulty analog inputs to the A/D converter.

OR

The stop/start capacitor control module detects a capacitor voltage of 5.86 V or greater, indicating the capacitor voltage sensor is stuck at maximum.

P106A 

The stop/start capacitor control module detects a voltage drop across the internal ground switch greater than 0.8 V or less than -0.8 V when current is greater than 550 A.

OR

The stop/start capacitor control module detects a voltage drop across the internal ground switch greater than 0.4 V or less than -0.4 V when current is less than or equal to 550 A.

P106B 

The stop/start capacitor control module detects an internal ground switch driver voltage bank is less than 10.46 V.

P106C 

The stop/start capacitor control module detects an internal ground switch is in high impedance state.

P106D 

The stop/start capacitor control module detects the internal safety supply voltage is less than 11.23 V.

P1071 

The stop/start capacitor control module detects a failure of the Read Only Memory (ROM).

P1072 

The stop/start capacitor control module detects a failure of the Random Access Memory (RAM).

P1073 

The stop/start capacitor control module detects a failure of the Erasable Programmable Read Only Memory (EPROM).

P1080 

The stop/start capacitor control module detects an internal ground switch bank A gate voltage is less than 10.5 V when switch is commanded close.

P1081 

The stop/start capacitor control module detects an internal ground switch bank A gate voltage is greater than 2.0 V when switch is commanded open.

P108A 

The stop/start capacitor control module detects the absolute value of the difference between the ground switch bank A and bank B gate voltage is greater than 2.0 V.

P108B 

The stop/start capacitor control module detects an internal ground switch bank B gate voltage is less than 10.5 V when switch is commanded close.

P108C 

The stop/start capacitor control module detects an internal ground switch bank B gate voltage is greater than 2.0 V when switch is commanded close.

P108D 

The stop/start capacitor control module detects the DC/DC converter does not stop charging when requested or is unable to discharge the capacitor

P108E 

The stop/start capacitor control module detects the phase 1 charge current is greater than 36.75 A or phase 2 charge current is greater than 68.25 A.

OR

The stop/start capacitor control module detects the DC/DC converter is unable to charge the capacitor

P108F 

The stop/start capacitor control module detects that it is unable to switch over to the internal capacitor switch during self test.

OR

The stop/start capacitor control module detects an unintended switchover to the capacitor switch during self test.

OR

The stop/start capacitor control module detects the capacitor switch is in a high impedance state or diode mode during self test.

P1090 

The stop/start capacitor control module detects less than 2.18 V or greater than 2.83 V on a 2.5 V reference.

P1091 

The stop/start capacitor control module detects capacitor switch current is greater than 60 A and ground switch current is less than -120 A.

OR

The stop/start capacitor control module detects ground switch current is greater than 40 A and capacitor switch current is less than 30 A

OR

The stop/start capacitor control module detects capacitor switch is in a high impedance or in diode mode when it should be closed.

OR

The stop/start capacitor control module detects capacitor switch does not close when it is commanded to close.

OR

The stop/start capacitor control module has reached its end of life.