Conditions for Setting the DTC
WARNING: This page is about a different variant/trim than selected.
Condition 1
TCM detects an internal temperature condition of 146°C (295°F) or greater for 5 s.
Condition 2
Ignition voltage is 18 V or greater and the TCM detects an internal temperature of 50°C (122°F) or greater for 2 s.