Fluid Pressure Directed in Preparation for a Shift
WARNING: This page is about a different variant/trim than selected.
Manual Valve
With the manual valve in the reverse position, line pressure is directed into the reverse fluid circuit to the #2 ball check valve and clutch select valve 3.
#2 Ball Check Valve
Reverse fluid seats the #2 ball check valve against the solenoid 1 fluid passage and fluid is forced through orifice #15 into the CSV2 enable circuit.
Clutch Select Valve 2
CSV2 enable fluid, present at the valve from Park position, continues to hold the clutch select valve 2 against clutch select valve 2 spring force.