3-5 Reverse Clutch Applies
35R Pressure Control Solenoid 2
The 35R pressure control solenoid 2 is energized (HIGH) allowing actuator feed limit fluid to enter the PCS 3-5 reverse clutch circuit. PCS 3-5 reverse clutch fluid is then routed through orifice #36 to the 3-5 reverse clutch regulator valve and through orifice #37 to the 3-5 reverse boost valve.
3-5 Reverse Clutch Regulator Valve
PCS 3-5 reverse clutch fluid moves the 3-5 reverse clutch regulator valve against 3-5 reverse clutch regulator valve spring force and 3-5 reverse clutch feedback fluid. This allows 3-5 reverse feed to pass through the valve and enter the 3-5 reverse clutch circuit. The 3-5 reverse clutch fluid is then routed to the 3-5 reverse clutch and the 3-5 reverse boost valve. PS2 fluid from pressure switch 2 exhausts through the valve allowing the switch to close.
3-5 Reverse Boost Valve
PCS 3-5 reverse clutch fluid pressure acts on a differential area moving the 3-5 reverse clutch boost valve against the 3-5 reverse clutch boost valve spring. The 3-5 reverse clutch fluid passes through the valve and enters the 3-5 reverse clutch feedback circuit. As PCS 3-5 reverse clutch fluid pressure is increased to a given value, the 3-5 reverse clutch boost valve opens the 3-5 reverse clutch feedback circuit to exhaust. This results in the 3-5 reverse clutch regulator valve moving to the full feed position sending full 3-5 clutch reverse feed pressure (full line pressure) to the clutch.
3-5 Reverse Clutch
The 3-5 reverse clutch fluid enters the 3-5R/456 clutch housing to move the piston against spring force and compensator feed fluid to apply the 3-5 reverse clutch plates.