LEMON Manuals: Even more car manuals for everyone
Home >> GMC >> 2013 >> Yukon Base, RWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 1165 (Automatic Transmission - 6L50/6L80/6L90 - Introduction (1 Of 2)) >> Scan Tool Data List

Scan Tool Data List

WARNING: This page is about a different car, the 2008 Cadillac CTS. However, it is still accessible from the selected car via links, so may be relevant.

Use the Scan Tool Data List under the following conditions:

The values below represent a typical display recorded from a properly functioning system.

IMPORTANT: Do not use a scan tool that displays faulty data. Report the condition to the scan tool manufacturer. The use of a faulty scan tool can result in misdiagnosis and the unnecessary replacement of parts.

Only the parameters listed below are used in this manual for diagnosing. If a scan tool displays other parameters, the values are not recommended by General Motors for use in diagnosis.

Scan tool values below were recorded under the following conditions:

Scan Tool Parameter Data List* Units Displayed Typical Data Value
1-2 Shift Time F0, F2 Seconds Varies
2-3 Shift Time F0, F2 Seconds Varies
3-4 Shift Time F0, F2 Seconds Varies
4-5 Shift Time F0, F2 Seconds Varies
5-6 Shift Time F0, F2 Seconds Varies
Brake Switch F0, F1, F2 Applied/Released Released
Calc. Throttle Position F0, F1, F2 % Varies
Commanded Gear F0, F1, F2, F3 1, 2, 3, 4 or 1, 2, 3, 4, 5 or Park/Neutral, Reverse, 1, 2, 3, 4, 5 1, 2, 3, 4, 5, or 6
Driver Shift Control F0 Active/Inactive Inactive
Driver Shift Request F0 Upshift/ Downshift/ None/ Invalid None
ECT F0, F1, F2 °C (°F) Varies
Engine Speed F0, F1, F2 RPM Varies
Engine Torque F0, F1, F2 N.m (lb ft) Varies
Gear Ratio F0, F1, F2, F3 Ratio Varies
High Side Driver 2 F1, F2, F3 Enabled/Disabled Enabled
High Side Driver 2 CKT Status F1, F2, F3 OK, Open/Short to Volts, Short to GND, Indeterminate OK
Ignition Voltage F0, F2, F3 Volts 12-14
IMS F0, F2 Park-Drive 1, Open, Invalid Park
IMS A/B/C/P F0, F2 HI/LOW Varies
ISS/OSS Supply Voltage F0, F1, F2 OK, Out of Range OK
Last Shift Time F0, F2 Seconds Varies
Line PC Sol. CKT Status F3 OK, Open/Short to GND, Short to Volts, Indeterminate OK
Line PC Sol. Pressure Command F0, F3 kPa (psi) Varies
PC Sol. 2 CKT Status F3 OK, Open/Short to GND, Short to Volts, Indeterminate OK
PC Sol. 2 Pressure Comm F0, F3 kPa (psi) Varies
PC Sol. 3 CKT Status F3 OK, Open/Short to GND, Short to Volts, Indeterminate OK
PC Sol. 3 Pressure Comm F0, F3 kPa (psi) Varies
PC Sol. 4 CKT Status F3 OK, Open/Short to GND, Short to Volts, Indeterminate OK
PC Sol. 4 Pressure Comm F0, F3 kPa (psi) Varies
PC Sol. 5 CKT Status F3 OK, Open/Short to GND, Short to Volts, Indeterminate OK
PC Sol. 5 Pressure Comm F0, F3 kPa (psi) Varies
Shift Sol. 1 CKT Status F3 OK, Open/Short to GND, Short to Volts, Indeterminate OK
Shift Solenoid 1 F3 On/Off On
Shift Sol. 2 CKT Status F3 OK, Open/Short to GND, Short to Volts, Indeterminate OK
Shift Solenoid 2 F3 On/Off On
TCC PC Sol. Pressure Comm F0, F1, F3 kPa (psi) Varies
TCC Slip Speed F0, F1, F2 RPM Varies
TCM Temperature F0, F1, F2 °C (°F) Varies
TFP Switch 1 F0 HI/LOW HI/LOW
TFP Switch 3 F0 HI/LOW HI/LOW
TFP Switch 4 F0 HI/LOW HI/LOW
TFP Switch 5 F0 HI/LOW HI/LOW
Trans. Fluid Temp. F0, F1, F2 °C (°F) Varies
Transmission ISS F0, F1, F2 RPM Varies
Transmission OSS F0, F1, F2 RPM Varies

*Data List Legend

  • F0: Transmission Data
  • F1: TCC Data
  • F2: Shift Data
  • F3: Solenoid Data