Circuit/System Testing
Daytime Running Lamp Malfunction - with X88/Z88 and Z75 without T4Q
- Ignition OFF, disconnect the X4 harness connector at the BCM.
- Ignition ON, verify a test lamp illuminates between the relay control circuit terminal 23 and ground.
- If the test lamp does not illuminate, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the underhood fuse block.
- Ignition OFF, reconnect the X4 harness connector at the BCM.
- Disconnect the X4 harness connector at the underhood fuse block.
- Ignition ON, verify a test lamp does not illuminate between the relay control circuit terminal H4 and ground.
- If the test lamp illuminates, test the control circuit for a short to voltage. If the circuit tests normal, replace the BCM.
- Ignition OFF, reconnect the X4 harness connector at the underhood fuse block.
- Disconnect the harness connector at the appropriate daytime running lamp.
- Test for less then 5 Ω between the ground circuit listed below and ground.
- Terminal B (Z75)
- Terminal C (X88/Z88)
- If less than the specified range, test the ground circuit for an open/high resistance.
- Ignition OFF, connect a test lamp between the control circuit terminal A and ground.
- Ignition ON, command the DRL ON and OFF with a scan tool. The test lamp should turn ON and OFF.
- If the test lamp is always ON, test the control circuit for a short to voltage. If the circuit tests normal, replace the underhood fuse block.
- If the test lamp is always OFF, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the underhood fuse block.
- If all circuits test normal, replace the appropriate daytime running lamp.
Ambient Light Sensor Malfunction
- Ignition OFF, disconnect the harness connector at the ambient light sensor.
- Ignition OFF, test for less than 5 Ω between the ground circuit terminal listed below and ground.
- Terminal C (with CJ2)
- Terminal B (without CJ2)
- If greater than the specific range, test the ground circuit for an open/high resistance.
- Ignition ON, verify the scan tool Ambient Light Sensor parameter is greater than 4.65 V.
- If less than the specified range, test the signal circuit terminal for a short to ground. If the circuit tests normal, replace the BCM.
- Install a 3 A fused jumper wire between the signal circuit terminal listed below and the ground circuit terminal. Verify the scan tool Ambient Light Sensor parameter is less than 0.196 V.
- Terminal D (with CJ2)
- Terminal A (without CJ2)
- If greater than the specified range, test the signal circuit for a short to voltage an open/high resistance. If the circuit tests normal, replace the BCM.
- If all circuits test normal, replace the ambient light sensor.