Diagnostic Fault Information
| Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
|---|---|---|---|---|
| 12 V Reference | 1 | 1 | - | - |
| 5 V Reference | B3606 01 | B3606 06 | B3606 06 | - |
| Position Sensor Signal | B3606 06 | B3606 06 | B3606 06 | - |
| Forward Switch Signal | 2 | 2 | B3604 01 | - |
| Rearward Switch Signal | 3 | 3 | B3605 01 | - |
| Motor Control A | 1 | 1 | 1 | - |
| Motor Control B | 1 | 1 | 1 | - |
| Low Reference | - | B3606 06 | - | - |
| 1. Adjustable Pedals Inoperative 2. Adjustable Pedals Forward Inoperative 3. Adjustable Pedals Rearward Inoperative |
||||