Circuit/System Testing
- Ignition OFF, disconnect the harness connector at the EOP switch.
- Ignition OFF, test for less than 1 ohm between the low reference circuit terminal B and ground.
- If greater than the specified range, test the low reference circuit for an open/high resistance. If the circuit tests normal, replace the ECM.
- Ignition ON, verify the scan tool Engine Oil Pressure Switch parameter is OK.
- If not the specified value, test the signal circuit for a short to ground. If the circuit tests normal, replace the ECM.
- Ignition ON, install a 3 A fused jumper wire between the signal circuit terminal A and the ground circuit terminal B. Verify the scan tool Engine Oil Pressure Switch parameter is Low.
- If not the specified value, test the signal circuit for an open/high resistance. If circuit test normal, replace the ECM.
- Ignition ON, command the IPC indicators OFF with the scan tool.
- If the EOP indicator does not turn OFF, replace the IPC.
- If all circuits test normal, test or replace the engine oil pressure switch.