Circuit/System Verification
WARNING: This page is about a different variant/trim than selected.
P0A2B and P0A31
- Allow the vehicle to cool to ambient temperature by leaving the ignition OFF for at least 6 hours.
- Ignition ON, observe Motor 1 temperature, Motor 2 temperature, and phase U, V, W inverter temperature scan tool parameters.
- The Motor 1 Temperature, Motor 2 Temperature, and phase U, V, W inverter temperature parameters should be within 28°C (50°F) of each other and ambient temperature.
P0A2C, P0A2D, P0A32, and P0A33
Ignition ON, observe the motor control modules motor temperature scan tool parameter.
- The motor temperature parameter should be between 0.29 V and 4.42 V.