LEMON Manuals: Even more car manuals for everyone
Home >> GMC >> 2011 >> Yukon Base, 5.3 3 >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 14 (Engine Controls And Fuel - Hybrid (LZ1) - DTC P0351 Through DTC P3449 And Troubleshooting) >> Diagnostic Information and Procedures >> DTC P0443 or P0449 >> Circuit/System Testing

Circuit/System Testing

WARNING: This page is about a different variant/trim than selected.
  1. Ignition OFF, disconnect the harness connector at the EVAP canister purge or vent solenoid valve.
  2. Ignition ON, verify that a test lamp illuminates between the voltage supply circuit terminal A and ground.
    • If the test lamp does not illuminate, test the voltage supply circuit for a short to ground or an open/high resistance. If the circuit tests normal and the voltage supply circuit fuse is open, test or replace the EVAP canister purge solenoid.
  3. Connect a test lamp between the voltage supply circuit terminal A and the control circuit terminal B.
  4. Command the EVAP canister purge solenoid valve to 50 percent with a scan tool, or the EVAP canister vent solenoid valve ON and OFF. The test lamp should respond to the command.
    • If the test lamp is always ON, test the control circuit for a short to ground. If the circuit tests normal, replace the ECM.
    • If the test lamp is always OFF, test the control circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the ECM.
  5. If all circuits test normal, replace the appropriate solenoid valve.