HUD Intensity Does Not Vary
- Ignition OFF, disconnect the harness connector at the HUD module.
- Connect a test lamp between the B+ voltage circuit terminal 6 and the HUD off/dimming switch signal circuit terminal 5.
- Ignition ON, verify that the test lamp illuminates and changes intensity when the HUD off/dimming switch is adjusted from low to high intensity.
- If the test lamp does not vary in intensity, test the signal circuit for an open/high resistance. If the circuit tests normal, replace the HUD switch.